manual knife gate valve

  • wcb stainless steel a216 cast steel knife gate valve
  • wcb stainless steel a216 cast steel knife gate valve
  • wcb stainless steel a216 cast steel knife gate valve
  • wcb stainless steel a216 cast steel knife gate valve
  • wcb stainless steel a216 cast steel knife gate valve
  • wcb stainless steel a216 cast steel knife gate valve
  • wcb stainless steel a216 cast steel knife gate valve
  • wcb stainless steel a216 cast steel knife gate valve
  • wcb stainless steel a216 cast steel knife gate valve
  • wcb stainless steel a216 cast steel knife gate valve
  • wcb stainless steel a216 cast steel knife gate valve
  • wcb stainless steel a216 cast steel knife gate valve

wcb stainless steel a216 cast steel knife gate valve

wcb stainless steel a216 cast steel knife gate valve

ApplicationGeneralPlace of OriginShenzhen, China
PowerManualCustomized supportOEM, ODM, OBM
Warranty3 yearsModel Numbergate valve
Temperature of MediaHigh Temperature, Low Temperature, Medium Temperature, Normal TemperatureBrand NameEATHU
MediaWaterStandard or NonstandardStandard
Nameknife gate valveStandardAWWA,DIN3352,BS5163,BS5150
Body materialCast iron, Ductile iron, stainless steelStemRising, Non rising
SealMetal or resilientPressurePN10/16/25, Class125/150
SurfaceExpoxy coatingface to faceDIN3202 F4/F5, ANSI B16.1,BS EN558-1
TestEN 12266-1:2003


1. Introduction

The WCB Stainless Steel A216 Cast Steel Knife Gate Valve is designed for reliable performance in industrial applications where durability and resistance to wear are essential. This valve is suitable for handling various types of media, including slurries, viscous fluids, and corrosive substances, making it ideal for industries such as mining, wastewater treatment, and chemical processing.

2. Features

  • Material: WCB (cast carbon steel) body with stainless steel trim for enhanced corrosion resistance.
  • Design: Knife gate design to cut through thick and abrasive media, ensuring smooth flow and minimal clogging.
  • Seal: Resilient seal providing tight closure and preventing leakage.
  • Actuation: Available in manual, pneumatic, or electric actuation options.
  • Connection: Flanged ends for easy installation and secure connection.
  • Pressure Rating: Suitable for medium to high-pressure applications.

3. Applications

  • Mining industry.
  • Wastewater treatment plants.
  • Pulp and paper industry.
  • Chemical processing.
  • Power plants.

4. Technical Specifications

ParameterSpecification
Valve SizeVarious sizes available
Body MaterialWCB (A216 Cast Steel)
Gate MaterialStainless Steel (SS304/SS316)
Seal MaterialResilient (EPDM, NBR, etc.)
Pressure RatingPN10, PN16, or higher
Temperature Range-10°C to 120°C (14°F to 248°F)
Connection TypeFlanged
Face-to-Face DimensionAccording to ISO 5752
MediaSlurry, abrasive and viscous fluids
Operating Pressure1.0 MPa (PN10) or higher
ActuationManual, Pneumatic, Electric
Air Supply Pressure (Pneumatic)0.4 - 0.7 MPa
Leakage RateZero leakage (resilient seal)
Testing StandardAPI 598

5. Installation Instructions

  1. Preparation: Ensure the pipeline is clean and free of debris.
  2. Alignment: Align the valve with the pipeline flanges.
  3. Bolting: Secure the valve using appropriate bolts and nuts, ensuring even tightening.
  4. Actuation Connection:
    • For pneumatic actuators, connect the actuator to the air supply according to the manufacturer’s instructions.
    • For electric actuators, ensure proper electrical connections are made.
  5. Testing: Test the valve for proper operation and check for leaks.

6. Maintenance

  • Regular Inspection: Periodically inspect the valve and actuator for signs of wear or damage.
  • Seal Replacement: Replace the seals if leakage is detected.
  • Stem Maintenance: Ensure the stem operates smoothly and is free from debris.
  • Actuator Maintenance: Follow the actuator manufacturer’s maintenance guidelines.

7. Safety Precautions

  • Ensure the air supply or electrical power is disconnected before performing any maintenance.
  • Use appropriate personal protective equipment (PPE) when handling the valve.
  • Follow all relevant safety standards and guidelines.

8. Troubleshooting

IssuePossible CauseSolution
Valve does not open/closeObstruction in the gate areaInspect and clean the gate area
Leakage through the sealWorn or damaged sealReplace the seal
Actuator malfunctionAir supply issue or actuator failureCheck air supply and inspect the actuator (for pneumatic) or check electrical connections (for electric)