manual knife gate valve

  •  PN16 Cast Iron /Steel Slurry Hydraulic/Manual Resilient Seal Flange Knife Gate Valve
  •  PN16 Cast Iron /Steel Slurry Hydraulic/Manual Resilient Seal Flange Knife Gate Valve
  •  PN16 Cast Iron /Steel Slurry Hydraulic/Manual Resilient Seal Flange Knife Gate Valve
  •  PN16 Cast Iron /Steel Slurry Hydraulic/Manual Resilient Seal Flange Knife Gate Valve
  •  PN16 Cast Iron /Steel Slurry Hydraulic/Manual Resilient Seal Flange Knife Gate Valve
  •  PN16 Cast Iron /Steel Slurry Hydraulic/Manual Resilient Seal Flange Knife Gate Valve
  •  PN16 Cast Iron /Steel Slurry Hydraulic/Manual Resilient Seal Flange Knife Gate Valve
  •  PN16 Cast Iron /Steel Slurry Hydraulic/Manual Resilient Seal Flange Knife Gate Valve
  •  PN16 Cast Iron /Steel Slurry Hydraulic/Manual Resilient Seal Flange Knife Gate Valve
  •  PN16 Cast Iron /Steel Slurry Hydraulic/Manual Resilient Seal Flange Knife Gate Valve
  •  PN16 Cast Iron /Steel Slurry Hydraulic/Manual Resilient Seal Flange Knife Gate Valve
  •  PN16 Cast Iron /Steel Slurry Hydraulic/Manual Resilient Seal Flange Knife Gate Valve

PN16 Cast Iron /Steel Slurry Hydraulic/Manual Resilient Seal Flange Knife Gate Valve

PN16 Cast Iron /Steel Slurry Hydraulic/Manual Resilient Seal Flange Knife Gate Valve

ApplicationGeneralPlace of OriginShenzhen, China
PowerManualCustomized supportOEM, ODM, OBM
Warranty12 MonthsTemperature of MediaMedium Temperature, Normal Temperature
Brand NameCHXMediaWater
PressureJIS10-20K, ANSI Class 150-900, Pn1.0-32.0MPaBody materialWcb/Stainless Steel/SS304/SS316
Connection typeFlange,Thread,GroovedColorBlue, Red, Green, Black, Silver, Grey
MediumWater Oil GasDrive WayWorm Gear, Pneumatic, Manual, Hydraulic, Electric
UsageIndustrial UsageMOQ1 Pc
CertificationISO,EAC,WRAS,CETypeGate Valves


1. Introduction

The PN16 cast iron/steel slurry hydraulic/manual resilient seal flange knife gate valve is designed for handling abrasive and corrosive slurry applications. It features a robust construction with a resilient seal to ensure tight closure and prevent leakage. This valve is suitable for industries such as mining, wastewater treatment, and pulp & paper.

2. Features

  • Material: Cast iron or steel body for durability and strength.
  • Seal: Resilient seal providing tight closure and preventing leakage.
  • Design: Knife gate design to cut through thick media, ensuring smooth flow and minimal clogging.
  • Actuation: Available in both hydraulic and manual operation.
  • Connection: Flanged ends for easy installation and secure connection.

3. Applications

  • Mining industry.
  • Wastewater treatment plants.
  • Pulp and paper industry.
  • Chemical processing industry.
  • Power plants.

4. Technical Specifications

ParameterSpecification
Valve Size4 inches (DN100) and other sizes available
Body MaterialCast Iron / Steel
Gate MaterialStainless Steel (SS304/SS316)
Seal MaterialResilient (EPDM, NBR, etc.)
Pressure RatingPN16
Temperature Range-10°C to 120°C (14°F to 248°F)
Connection TypeFlanged
Face-to-Face DimensionAccording to ISO 5752
MediaSlurry, abrasive fluids, corrosive substances
Operating Pressure1.6 MPa
Actuation OptionsHydraulic, Manual
Leakage RateZero leakage (resilient seal)
Testing StandardAPI 598

5. Installation Instructions

  1. Preparation: Ensure the pipeline is clean and free of debris.
  2. Alignment: Align the valve with the pipeline flanges.
  3. Bolting: Secure the valve using appropriate bolts and nuts, ensuring even tightening.
  4. Actuator Connection: If using a hydraulic actuator, connect it according to the manufacturer's instructions.
  5. Testing: Test the valve for proper operation and check for leaks.

6. Maintenance

  • Regular Inspection: Periodically inspect the valve for signs of wear or damage.
  • Seal Replacement: Replace the seals if leakage is detected.
  • Stem Maintenance: Ensure the stem operates smoothly and is free from debris.
  • Actuator Maintenance: Follow the actuator manufacturer's maintenance guidelines if applicable.

7. Safety Precautions

  • Ensure the hydraulic or power supply is disconnected before performing any maintenance.
  • Use appropriate personal protective equipment (PPE) when handling the valve.
  • Follow all relevant safety standards and guidelines.

8. Troubleshooting

IssuePossible CauseSolution
Valve does not open/closeObstruction in the gate areaInspect and clean the gate area
Leakage through the sealWorn or damaged sealReplace the seal
Actuator malfunction (if applicable)Actuator failureInspect and repair/replace actuator